Skip to main content
Log in

Dynamometer for rat plantar flexor musclesin vivo

  • Communication
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A dynamometer is designed and fabricated to measure the force output during static and dynamic muscle actions of the plantar flexor muscles of anaesthetised rats in vivo. The design is based on a computer-controlled DC servomotor capable of angular velocities in excess of 17.5 rad s−1. The system controls the range of motion, angular velocity and electrical stimulation of the muscles, while monitoring the force output at the plantar surface of the foot. The force output is measured by a piezo-electric load cell that is rated at 5 kg capacity. Angular velocity and position are measured by a DC tachometer and potentiometer, respectively. All measurement devices are linear (r2=0.9998). The design minimises inertial loading during high-speed angular motions, with a variation in force output of less than 0.2%. The dynamometer proves to be an accurate and reliable system for quantifying static and dynamic forces of rat plantar flexor muscles in vivo.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Ashton-Miller, J. A., Youda, H., Veerichetty, A. K., McCubbrey, D. A., andFaulkner, J. A. (1992): ‘An apparatus to measurein vivo biomechanical behavior of dorsi and plantar flexors of the mouse ankle’,J. Appl. Physiol.,72, pp. 1205–1211

    Google Scholar 

  • Bahler, A. S., Fales, J. T. andZierler, K. L. (1968): ‘The dynamic properties of mammalian skeletal muscle’,J. Gen. Physiol.,51, pp. 369–384

    Article  Google Scholar 

  • Farrell, M. andRichards, J. E. (1986): ‘Analysis of the reliability and validity of the kinetic communicator exercise device’,Med. Sci. Sports Exerc.,18, pp. 44–49

    Google Scholar 

  • Faulkner, J. A. andJones, D. A. (1989): ‘Injury to skeletal muscles of mice by forced lengthening during contractions’,Q. J. Exper. Physiol.,74, pp. 661–670

    Google Scholar 

  • Lewis, J. L., Lew, W. D. andSchmidt, J. (1982): ‘A note on the application and evaluation of the buckle transducer for knee ligament force measurement’,J. Biomech. Eng.,104, pp. 125–128

    Article  Google Scholar 

  • Lieber, R. L. andFriden, J. (1988): ‘Selective damage of fast glycolytic muscle fibers with eccentric contraction of the rabbit tibialis anterior’,Acta Physiol. Scand.,3, pp. 587–588

    Article  Google Scholar 

  • Nikolaou, P. K., MacDonald, B. L., Glisson, R. R., Seaber, A. V., andGarrett, W. E. (1987): ‘Biomechanical and histological evaluation of muscle after controlled strain injury’,Am. J. Sports Med.,15, pp. 9–14

    Google Scholar 

  • Walmesley, B., Hodgson, J. A. andBurke, R. E. (1978): ‘Forces produced by medial gastrocnemius and soleus muscles’,J. Neurophysiol.,41, pp. 1203–1216

    Google Scholar 

  • Warren, G. L., Hayes, D. A., Lowe, D. A. andArmstong, R. B. (1993): ‘Mechanical factors in the initiation of eccentric contraction induced injury of the rat soleus muscle’,J. Physiol. Lond.,464, pp. 457–475

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to W. T. Stauber.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cutlip, R.G., Stauber, W.T., Willison, R.H. et al. Dynamometer for rat plantar flexor musclesin vivo . Med. Biol. Eng. Comput. 35, 540–543 (1997). https://doi.org/10.1007/BF02525537

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02525537

Keywords

Navigation