Skip to main content

Advertisement

Log in

Postoperative erosions of the Mersilene® suburethral sling mesh for antiincontinence surgery

  • Original Article
  • Published:
International Urogynecology Journal Aims and scope Submit manuscript

Abstract

The objective of the study was to describe the presentation of vaginal mesh erosions following Mersilene® suburethral slings for urinary incontinence. We performed a retrospective review of all Mersilene® suburethral slings placed at a tertiary referral center from 1996 to 2007. A total of 772 women underwent placement of a Mersilene® suburethral sling. We identified 62 women that underwent surgical revision due to mesh erosion for an overall erosion rate of 8%. The most common presenting symptom was vaginal discharge reported in 37% of women. Other symptoms included vaginal bleeding in 31%, pain or dyspareunia in 13%, and voiding dysfunction in 21% of women. Seven women were found to have the mesh in the bladder on cystoscopy. Cellulitis complicated 8.3% of erosions. Patients with erosions of Mersilene® mesh slings commonly complain of vaginal bleeding and discharge and may present up to 20 years after the surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Hohenfellner R, Petrie E (1986) Sling procedures. In: Stanton SL, Tanagho E (eds) Surgery of Female Incontinence, 2nd edn. Springer, Berlin, pp 105–113

    Google Scholar 

  2. Tizzano A (2007) Historical milestones in female pelvic surgery, gynecology, and female urology. In: Walters MD, Karram MM (eds) Urogynecology and Reconstructive Pelvic Surgery ed 3. Mosby: 4–12

  3. Ridley JH (1955) Surgical treatment of stress urinary incontinence in women. J Med Assoc Georgia 44:135

    CAS  Google Scholar 

  4. Williams TJ, TeLinde RW (1962) The sling operation for urinary incontinence using mersilene ribbon. Obstet Gynecol 19(2):241–245

    PubMed  CAS  Google Scholar 

  5. Young SB, Rosenblatt PL, Pingeton DM, Howard AE, Baker SP (1995) The Mersilene mesh suburethral sling: a clinical and urodynamic evaluation. Am J Obstet Gynecol 173(6):1719–1726

    Article  PubMed  CAS  Google Scholar 

  6. Moir JC (1968) The Gauze-Hammock operation. Br J Obstet Gynaecol 75(1):1–9

    CAS  Google Scholar 

  7. Nichols DH, Randall CL (1996) Choice of operation for urinary stress incontinence. In: Nichols DH, Randall CL (eds) Vaginal surgery, 4th edn. Williams & Wilkins, Baltimore, pp 384–421

    Google Scholar 

  8. Nichols DH (1973) The Mersilene mesh gauze-hammock for severe urinary stress incontinence. Obstet Gynecol 41(1):88–93

    PubMed  CAS  Google Scholar 

  9. Persson J, Iosif C, Wolner-Hanssen P (2002) Risk factors for rejection of synthetic suburethral slings for stress urinary incontinence: a case–control study. Obstet Gynecol 99(4):629–634

    Article  PubMed  Google Scholar 

  10. Karram MM, Segal JL, Vassallo BJ, Kleeman SD (2003) Complications and untoward effects of the tension-free vaginal tape procedure. Obstet Gynecol 101(5):929–932

    Article  PubMed  Google Scholar 

  11. Iglesia CB, Fenner DE, Brubaker L (1997) The use of mesh in gynecologic surgery. Int Urogynecol J Pelvic Floor Dysfunct 8(2):105–155

    Article  PubMed  CAS  Google Scholar 

  12. Visco AG, Weidner AC, Barber MD, Myers ER, Cundiff GW, Bump RC, Addison WA (2001) Vaginal mesh erosion after abdominal sacral colpopexy. Obstet Gynecol Surv 56(7):410–411

    Article  Google Scholar 

  13. Timmons MC, Addison WA (1997) Mesh erosion after abdominal sacrocolpopexy. J Pelvic Surg 3:75–80

    Google Scholar 

  14. Young SB, Howard AD, Baker SP (2001) Mersilene mesh sling: short- and long-term clinical and urodynamic outcomes. Am J Obstet Gynecol 185(1):32–40

    Article  PubMed  CAS  Google Scholar 

  15. Myers DL, LaSala CA (1998) Conservative surgical management of Mersilene mesh suburethral sling erosion. Am J Obstet Gynecol 179(6):1424–1429

    Article  PubMed  CAS  Google Scholar 

  16. Care New England Health System Annual Report. Fiscal Year 2006.

Further Reading

  1. Website: Rhode Island Department of Health www.health.ri.gov/chic/statistics/BRFSS2004Summary_smk.pdf

Download references

Conflicts of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kyle J. Wohlrab.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wohlrab, K.J., Erekson, E.A. & Myers, D.L. Postoperative erosions of the Mersilene® suburethral sling mesh for antiincontinence surgery. Int Urogynecol J 20, 417–420 (2009). https://doi.org/10.1007/s00192-008-0787-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00192-008-0787-4

Keywords

Navigation