Skip to main content
Log in

Quantification of diphosphonate uptake based on conventional bone scanning

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Up to now there has been no routinely used and easy-to-perform method for the quantification of bone uptake. Therefore, we have evaluated the clinical practicability of a new and simple method for the measurement of bone uptake based upon conventional three-phase bone scanning. In 13 patients with normal bone scans, whole-body scintigrams were obtained at 3 min and 1, 2, 3, 4, 5, 6 and 24 h after injection of 600 MBq technetium-99m hydroxymethylene diphosphonate (HMDP). Using a conventional region of interest technique, fitted time-activity curves of soft tissue and urinary excretion were established, and bone uptake was calculated from these data as the total whole-body activity minus both soft tissue activity and urinary excretion. Subsequently, the new method was tested in routine patient management: 32 healthy patients and five patients with different types of metabolic bone disease were investigated, measurements being performed only at 3 min and 3–4 h p.i. during conventional three-phase bone scanning. In the multi-imaged patient subset, soft tissue activity decreased exponentially, reaching a plateau after 6 h with a residual activity of about 14% of initial total whole-body activity. Bone uptake reached quite a stable plateau of about 27% as early as 3 h p.i., with no significant changes up to 24 h. Healthy patients of the two-scan group showed no differences in bone uptake (mean uptake values were 24.1% in women and 26.9% in men), whereas in patients with metabolic bone disease bone uptake was significantly higher, with a mean of 48% (P <0.05). Thus, the results of this method are in good agreement with the findings of standard 24-h whole-body retention measurements. The new method, however, is easy to perform, allows assessment of pure bone uptake instead of whole-body retention, and permits calculation of bone uptake by only two measurements during routine three-phase bone scanning.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 5 February and in revised form 27 June 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brenner, W., Bohuslavizki, K., Sieweke, N. et al. Quantification of diphosphonate uptake based on conventional bone scanning. Eur J Nucl Med 24, 1284–1290 (1997). https://doi.org/10.1007/s002590050153

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050153

Navigation