Skip to main content

Advertisement

Log in

Diagnosis of fatty infiltration of the liver on contrast enhanced CT: limitations of liver-minus-spleen attenuation difference measurements

  • Published:
Abdominal Imaging Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract

Background: We investigated whether liver-minus-spleen (L-S) attenuation differences can accurately diagnose fatty infiltration of the liver on contrast-enhanced computed tomography (CT).

Methods: A group of 78 patients administered a fast injection (90-s duration) of 150 mL 60% ionic contrast was compared with 81 patients given a slow injection (152.5 s). The presence or absence of fatty infiltration of the liver was diagnosed by noncontrast CT.

Results: The L-S attenuation differences varied significantly, depending on both injection rate and timing of measurements. For the fast-injection group, the optimal L-S threshold for diagnosing fatty infiltration ranged from −43 to −33 Hounsfield units (HU) for early (79 s) and late measurements (106 s), respectively. For the slow-injection group, the optimal threshold ranged from −31 to −25 HU (80 and 112 s, respectively). In addition, sensitivity was not very high (range = 0.54–0.71) for either injection protocol at any measurement time because of significant overlap of L-S values between normal and fatty infiltration patients. Moderate and severe fatty infiltration were more reliably diagnosed than mild fatty infiltration by this method.

Conclusions: Contrast injection rate and timing of measurements significantly influence the optimal L-S threshold for diagnosing fatty liver. This limits the clinical usefulness of such measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Johnston, R., Stamm, E., Lewin, J. et al. Diagnosis of fatty infiltration of the liver on contrast enhanced CT: limitations of liver-minus-spleen attenuation difference measurements. Abdom Imaging 23, 409–415 (1998). https://doi.org/10.1007/s002619900370

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002619900370

Key words

Navigation