Skip to main content
Log in

Press fit fixation of cementless cups: how much stability do we need indeed?

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Introduction: Using screws for a better primary and secondary fixation has been discussed in the literature of the recent years, although the principle of press fit has been explained as the principle of a push-button. The authors wanted to compare their own results in patients using X-rays from the postoperative course to decide if it is really safer to use screws or not. Materials and methods: Two hundred and twenty one consecutive, not selected patients were treated with total hip arthroplasty using a cementless cup type Duraloc. They were followed up over a time of 5 years for radiological changes of the bony acetabulum around the cup (“acetabular zones” according to De Lee and Charnley). One hundred and ten cups were additionally fixed with one to three screws at the upper part in region C1, 101 cups were implanted without the use of screws. Results: Periprosthetic changes visible on the radiographs (immediate postoperative gaps, subsequent sclerosis and radiolucent lines) were assessed according to the time of their appearance. A gap in zone C2 was seen more often immediately after operation within the group without screws (17.8% vs. 7.3%) and disappeared within the following 25 months. Within the group with screws significantly more often a gap was found in zone C1 and C3 compared to the group without screws (7.3% vs. 1.9%). In the group with screws a sclerosis of the bone in zone C1 developed in 32.7% mostly within the first 5 months. It was followed by a radiolucent line in zone C3 in 28.2% mainly within 5–25 months postoperatively and in zone C1 in 20.9% within 16 months. Significantly less seldom were these phenomena seen at the cups without screw fixation. There was no correlation between lateral or medial positioning and deviations from the ideal inclination to the bony changes around the cups. No signs of loosening occurred in either group. Conclusion: Less radiological changes around the cup if no screws were used and no disadvantages within this group led to the conclusion that an additional screw fixation in principle is not necessary in press-fit cups.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Adler E, Stuchin SA, Kummer FJ (1992) Stability of press-fit acetabular cups. J Arthroplasty 7:295–301

    Article  PubMed  CAS  Google Scholar 

  2. Bauer R, Kerschbaumer F, Poisel S, Oberthaler W (1979) The transgluteal approach to the hip joint. Arch Orthop Trauma Surg 95:7–49

    Article  Google Scholar 

  3. Cook SD, Barrack RL, Thomas KA, Haddad RJ Jr (1988) Quantitative analysis of tissue growth into human porous total hip components. J Arthroplasty 3:249–262

    Article  PubMed  CAS  Google Scholar 

  4. Cook SD, Thomas KA, Barrack RL, Whitecloud TS III (1992) Tissue growth into porous-coated acetabular components in 42 patients. Effects of adjunct fixation. Clin Orthop 283:163–170

    PubMed  Google Scholar 

  5. Curtis MJ, Jinnah RH, Wilson VD, Hungerford DS (1992) The initial stability of uncemented acetabular components. J Bone Joint Surg Br 74:372–376

    PubMed  CAS  Google Scholar 

  6. De Lee JG, Charnley J (1971) Radiological demarcation of cemented sockets in hip replacement. Clin Orthop Rel Res 121:20–33

    Google Scholar 

  7. Dorr LD, Wan Z, Cohen J (1998) Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop 351:58–168

    Google Scholar 

  8. Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80:382–390

    Article  PubMed  CAS  Google Scholar 

  9. Fisher DA (1999) 5 year review of second-generation acetabular cup with dome screws. J Arthroplasty 14:925–929

    Article  PubMed  CAS  Google Scholar 

  10. Hadjari MH, Hollis JM, Hofmann OE, Flahiff CM, Nelson CL (1994) Initial stability of porous coated acetabular implants. The effect of screw placement, screw tightness, defect type, and oversize implants. Clin Orthop 307:117–123

    PubMed  Google Scholar 

  11. Karas W (1994) Zur Stabilität zementfrei implantierter Hüftgelenkpfannen. Med Orth Tech 114:206–212

    Google Scholar 

  12. Keating EM, Ritter MA, Faris PM (1990) Structures at risk from medially placed acetabular screws. J Bone Joint Surg Am 72:509–511

    PubMed  CAS  Google Scholar 

  13. Kwong, LM, O‘Connor DO, Sedlacek RC, Krushell RJ., Maloney WJ, Harris WH (1994) A quantitative in vitro assessment of fit and screw fixation on the stability of cementless hemispherical acetabular component. J Arthroplasty 9:163–170

    Article  PubMed  CAS  Google Scholar 

  14. MacKenzie JR, Callaghan JJ, Pedersen DR, Brown TD (1994) Areas of contact and extent of gaps with implantation of oversized acetabular components in THA. Clin Orthop Rel Res 298:127–136

    Google Scholar 

  15. Morscher EW (1992) Current status of acetabular fixation in primary total hip arthroplasty. Clin Orthop 274:172–193

    PubMed  Google Scholar 

  16. Morscher E (1994) Prinzipien der Pfannenfixation bei der Hüftarthroplastik mit spezieller Berücksichtigung des Press-Fit Cup. Med Orth Tech 114:217–222

    Google Scholar 

  17. Morscher E, Bereiter H, Lampert C (1989) Cementless press-fit cup. Principles, experimental data, and three-year follow-up study. Clin Orthop 249:12–20

    PubMed  Google Scholar 

  18. Morscher E, Masar Z (1988) Development and first experience with an uncemented press-fit cup. Clin Orthop 232:96–103

    PubMed  Google Scholar 

  19. Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R (2002) Primary fixation of cementless press-fit cup in THA. Acta Chir Orthop Traumatol Czech 69:8–15

    CAS  Google Scholar 

  20. Perona PG, Lawrence J, Paprosky WG, Patwardhan AG, Sartori M (1992) Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty. An in vitro comparison of different methods of initial acetabular component fixation. J Arthroplasty 7:537–547

    Article  PubMed  CAS  Google Scholar 

  21. Ries MD, Harbaugh M (1997) Acetabular strains produced by oversized press fit cups. Clin Orthop 334:276–281

    PubMed  Google Scholar 

  22. Schmalzried TP, Harris WH (1992) The Harris-Galante porous-coated acetabular component with screw fixation. J Bone Joint Surg 74:1130–1138

    PubMed  CAS  Google Scholar 

  23. Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. J Arthroplasty 9:235–242

    Article  PubMed  CAS  Google Scholar 

  24. Stiehl JB, MacMillan E, Skrade DA (1991) Mechanical stability of porous-coated acetabular components in total hip arthroplasty. Arthroplasty 6:295–300

    Article  CAS  Google Scholar 

  25. Sumner DR, Jasty M, Jacobs JJ, Urban RM, Bragdon CR, Harris WH, Galante J (1993) Histology of porous-coated acetabular components. 25 cementless cups retrieved after arthroplasty. Acta Orthop Scand 64:619–626

    Article  PubMed  CAS  Google Scholar 

  26. Udomkiat P, Wan Z, Dorr LD (2001) Comparison of preoperative radiographs and intraoperative findings of fixation of hemispheric porous-coated sockets. J Bone Joint Surg Am 83-A:1865–1870

    PubMed  CAS  Google Scholar 

  27. Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 84-A:1195–1200

    PubMed  Google Scholar 

  28. Wasielewski RC, Cooperstein LA, Kruger MP, Rubash HE (1990) Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty. J Bone Joint Surg Am 72:501–508

    PubMed  CAS  Google Scholar 

  29. Won CH, Hearn TC, Tile M (1995) Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation? J Bone Joint Surg Br 77:484–489

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Roth.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Roth, A., Winzer, T., Sander, K. et al. Press fit fixation of cementless cups: how much stability do we need indeed?. Arch Orthop Trauma Surg 126, 77–81 (2006). https://doi.org/10.1007/s00402-005-0001-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-005-0001-9

Keywords

Navigation