Ultra high molecular weight polyethylene (UHMWPE) wear debris has been shown to be a major cause of long term failure of total joint replacements. Recently, crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear of non-crosslinked and crosslinked UHMWPE were compared under a range of conditions.
The materials examined were UHMWPE GUR 1050, non-crosslinked, moderately crosslinked—5MRad, and highly crosslinked—10MRad. The wear was examined on a multidirectional pin on plate rig. The effect of counterface roughness on wear under different kinematics was examined.
The results from the different counterface conditions showed that highly crosslinked UHMWPE had significantly lower wear against both smooth and scratched counterfaces. However the reduction in wear for crosslinked polyethylene was less for scratched counterfaces. The second part of the study showed that all the UHMWPE's produced lower wear rates under lower multidirectionality because of reduced cross shear frictional forces and work. These findings are relevant to the consideration of the use of crosslinked polyethylene in the knee, where the kinematics have lower levels of cross shear and in the hip and knee against roughened metallic counterfaces.
Similar content being viewed by others
References
T. P. SCHMALZRIED, M. JASTY and W. H. HARRIS, J. Bone Jt. Surg. 74-A, (1992) 849.
T. R. GREEN, J. FISHER, J. B. MATTHEWS, M. STONE and E. INGHAM, J. Biomed. Mater. Res. (Appl Biomats). 53 (2000) 490.
H. C. AMSTUTZ, P. CAMPBELL, N. KOSSOVSKY and I. C. CLARKE, Clin. Orthop. Rel. Res. 276 (1992) 7.
H. MCKELLOP, F. W. SHEN, W. DIMAIO and J. G. LANCASTER, Clin. Orthop. Rel. Res. 369 (1999) 73.
O. K. MURTAGOLU, C. R. BRAGDON, D. O. O'CONNOR, H. SKEHAN, J. DELANEY, M. JASTY and W. H. HARRIS, In Proceedings of 46th Annual meeting of the Orthopaedic Research Society. (2000) p.566.
M. M. ENDO, J. L. TIPPER, D. C. BARTON, M. H. STONE, E. INGHAM and J. FISHER, Proc. Instn. Mech. Eng. 216H (2002) 111.
O. R. MURATOGLU, C. R. BRAGDON, D. O. O'CONNOR, M. JASTY and W. H. HARRIS, J. Arthroplasty, 16 (2001) 149.
M. M. ENDO, P. S. M. BARBOUR, D. C. BARTON, J. FISHER, J. L. TIPPER, E. INGHAM and M. STONE, Biomed. Mater. Eng. 11 (2001) 23.
P. S. M. BARBOUR, M. H. STONE, J. FISHER (1999). In: DTI CAM Project, Accelerated test methods to predict the durability of materials and surface treatments employed for total hip replacements. Task 3.7. (1999).
J. FISHER, Cur. Ortho. 8 (1994) 164.
A. WANG, Wear, 248 (2001) 38.
P. S. M. BARBOUR, M. H. STONE and J. FISHER, Proc. Instn. Mech. Eng. 213H (1999) 455.
D. BENNETT, J. F. ORR, D. E. BEVERLAND and R. BAKER, Proc. Instn. Mech. Eng. 216H (2002) 393.
H. M. J. MCEWEN, Ph.D thesis, University of Leeds (2002).
C. M. POOLEY and D. TABOR, Proc. Royal Soc. Lon. A. 329 (1972) 251.
A. WANG, D. C. SUN, S. S. YAU, B. EDWARDS, M. SOKOL, A. ESSNER, V. K. POLINENI, C. STARK and J. H. DUMBLETON, Wear. 203–204 (1997) 230.
H. MINAKAWA, M. H. STONE, B. M. WROBLEWSKI, J. G. LANCASTER, E. INGHAM, J. FISHER, J. Bone Jt. Surg. 80-B (1998) 894.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Galvin, A., Kang, L., Tipper, J. et al. Wear of crosslinked polyethylene under different tribological conditions. J Mater Sci: Mater Med 17, 235–243 (2006). https://doi.org/10.1007/s10856-006-7309-z
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10856-006-7309-z