Skip to main content
Log in

Case Reports: Tantalum Debris Dispersion During Revision of a Tibial Component for TKA

  • Case Report
  • Published:
Clinical Orthopaedics and Related Research

Abstract

Porous tantalum nonmodular tibial components for TKA were introduced in 1999. We revised three well-fixed tantalum tibial trays. For removal, we used osteotomes and revision oscillating saw blades. Removal of the components was laborious and resulted in generation of abundant tantalum debris that seeded the periarticular soft tissues despite meticulous protection with gauze. The retained metallic debris that is visible on postoperative radiographs has the potential for generation of third-body wear. We alert the orthopaedic community about this phenomenon and recommend minimizing the use of motorized revision instruments for removal of trabecular metal implants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

References

  1. Cohen R. A porous tantalum trabecular metal: basic science. Am J Orthop. 2002;31:216.

    PubMed  Google Scholar 

  2. Cohn R, González Della Valle A, Cornell C. Similar wear in total hip arthroplasties with metallic and Zirconia femoral heads. HSS J. 2008;4:107–111.

  3. González Della Valle A, Leali A, Haas S. Etiology and surgical interventions for stiff total knee replacements. HSS J. 2007;3:182–189.

    Article  PubMed  Google Scholar 

  4. Klein GR, Levine HB, Hartzband MA. Removal of a well-fixed trabecular metal monoblock tibial component. J Arthroplasty. 2008;23:619–622.

    Article  PubMed  Google Scholar 

  5. Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials. 2006;27:4671–4681.

    Article  PubMed  CAS  Google Scholar 

  6. Malizos KN, Bargiotas K, Papatheodorou L, Hantes M, Karachalios T. Survivorship of monoblock trabecular metal cups in primary THA: midterm results. Clin Orthop Relat Res. 2008;466:159–166.

    Article  PubMed  Google Scholar 

  7. Nasser S, Poggie RA. Revision and salvage patellar arthroplasty using a porous tantalum implant. J Arthroplasty. 2004;19:562–572.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alejandro González Della Valle MD.

Additional information

Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.

Each author certifies that his or her institution has approved or waived approval for the human protocol for this investigation and that all investigations were conducted in conformity with ethical principles of research.

About this article

Cite this article

Sanchez Marquez, J.M., Del Sel, N., Leali, A. et al. Case Reports: Tantalum Debris Dispersion During Revision of a Tibial Component for TKA. Clin Orthop Relat Res 467, 1107–1110 (2009). https://doi.org/10.1007/s11999-008-0586-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-008-0586-8

Keywords

Navigation