Elsevier

Journal of Biomechanics

Volume 30, Issue 8, August 1997, Pages 829-835
Journal of Biomechanics

In vitro fatigue of human tendons

https://doi.org/10.1016/S0021-9290(97)00033-XGet rights and content

Abstract

The purpose of this study was to determine the fatigue behaviour of human tendons in vitro. The testing was accomplished with the use of specially designed grips and the local measurement of tendon cross-sectional area. Ninety specimens prepared from Extensor digitorum longus (EDL) tendons of the foot were subjected to a cyclic square tension-tension stress waveform at physiological frequencies. The maximum tensile stress was normalised to values corresponding to prescribed levels between 10% and 90% of the calculated ultimate tensile strength (UTS) of 100 MPa. The minimum stress was set at 1% of the UTS. A replication of 10 specimens per stress level allowed the use of statistical models for the distribution of fatigue life.

Results followed a linear model, of form S = 101.3 − 14.8 log(N), relating the normalised stress to the median number of cycles to failure, therefore suggesting the absence of an endurance limit. The Weibuil distribution was found to describe adequately the probability of failure at each stress level. A model which takes into account in vivo healing was proposed. This model was able to explain the presence of intact tendons throughout the lifetime of an individual.

References (33)

  • N.A.J. Hastings et al.
  • R.P. Hubbard et al.

    Mechanical properties of human tendons and their age dependence

    Journal of Biomechanical Engineering

    (1984)
  • L.G. Johnson
  • R.F. Ker et al.

    Why are mammalian tendons so thick?

    Journal of Zoology London

    (1988)
  • A.I. King et al.

    Analysis of fatigue strenght of human compact bone by the Weibull method

  • W. Krause et al.

    Fatigue properties of aerylic bone cement: S-N, P-N, and P-S-N data

    Journal of Biomedical Material Research

    (1988)
  • Cited by (173)

    • Low cycle fatigue properties of porcine aorta — Pilot study

      2023, Journal of the Mechanical Behavior of Biomedical Materials
    • Tensile fatigue strength and endurance limit of human meniscus

      2022, Journal of the Mechanical Behavior of Biomedical Materials
    View all citing articles on Scopus

    Current address: Departamento de Estudos em Ciencia e Tecnologica, Centro de Informacao Cientifica e Tecnologica, FIOCRUZ-Fundacao Oswaldo Cruz, Brazil.

    View full text