Dual-energy CT in the diagnosis and quantification of fatty liver: limited clinical value in comparison to ultrasound scan and single-energy CT, with special reference to iron overload

https://doi.org/10.1016/S0168-8278(98)80228-6Get rights and content

Abstract

Background/Aims: It has been suggested that dual-energy CT could differentiate irregular fatty liver from other hypodense lesions. We compared dual-energy CT to ultrasound scan and single-energy CT in the diagnosis and quantification of fatty liver, with special reference to iron overload.

Methods: Twenty-seven patients were included according to ultrasound: fatty liver (n=16) and normal liver (n=11). Single and dual-energy CT were performed. Attenuation measurements of hepatic lobes and control tissues were taken at 140 kV and 80 kV. CT-guided liver biopsy was done in fatty liver patients, the degree of infiltration was estimated, and the histologic iron overload determined (iron overload, n=11; iron-free, n=5).

Results: The mean changes in attenuation for the right hepatic lobe were: normal liver: −0.8 (ns); iron overloaded fatty liver: 1.5 (ns); and iron-free fatty liver: 7.7 (p<0.0053). A spleen-liver attenuation differential threshold of 12H (140 kV, single-energy CT) and a right hepatic lobe 140 kV to 80 kV attenuation differential threshold of 9 H (dual-energy CT) were specific for fatty liver. Histology confirmed all cases of fatty liver diagnosed by ultrasound, independently of iron overload. Ultrasound did not differentiate cases of irregular from diffuse fatty liver detected on CT. Iron overload produced a masking effect in CT, decreasing its sensitivity: fatty liver was diagnosed in 67% of cases by single-energy CT and in 20% by dual-energy CT. Degree of fatty infiltration correlated with single-energy CT.

Conclusions: Ultrasound diagnosed fatty liver best. Single-energy CT quantifies fatty infiltration, and best differentiates the irregular from the diffuse forms. Dual-energy CT is limited by poor sensitivity, especially in iron overload.

References (52)

  • S Patel et al.

    133Xe uptake in focal hepatic fat accumulation

    AJR

    (1982)
  • DH Stephens et al.

    Computed tomography of the liver

    AJR

    (1977)
  • M Behan et al.

    The echographic characteristics of fatty tissues and tumors

    Radiology

    (1978)
  • JKT Lee et al.

    Fatty infiltration of the liver; demonstration by proton spectroscopic imaging

    Radiology

    (1984)
  • CB Mulhern et al.

    Nonuniform attenuation in computed tomography study of the cirrhotic liver

    Radiology

    (1979)
  • WW Scott et al.

    Irregular fatty infiltration of the liver: diagnostic dilemmas

    AJR

    (1980)
  • HK Genant et al.

    Quantitative bone mineral analysis using dual-energy computed tomography

    Invest Radiol

    (1977)
  • AM Laval-Jeantet et al.

    A postprocessing dual energy technique for vertebral CT densitometry

    J Comput Assist Tomogr

    (1984)
  • JE Adams et al.

    Measurement of trabecular bone mineral by dual energy computed tomography

    J Comput Assist Tomogr

    (1982)
  • CE Cann et al.

    Spinal bone mineral determination in patients using dual energy computed tomography

    64th Scientific Assembly and Annual Meeting of the Radiological Society of North America

    (2611978)
  • CE Cann et al.

    Normal subjects vs. osteoporotics: no evidence using dual energy CT for disproportionate increase in vertebral marrow fat

    J Comput Assist Tomogr

    (1985)
  • R Pacifici et al.

    Single and dual energy tomographic analysis of spinal trabecular bone: a comparative study in normal and osteoporotic women

    J Clin Endocrinol Metab

    (1987)
  • HI Goldberg et al.

    Noninvasive quantitation of liver iron in dogs with hemochromatosis using dual-energy CT scanning

    Invest Radiol

    (1982)
  • RG Sephton

    The potential accuracy of dual-energy computed tomography for the determination of hepatic iron

    Br J Radiol

    (1986)
  • RWG Chapman et al.

    Computed tomography for determining liver iron content in primary haemochromatosis

    Br Med J

    (1980)
  • V Raptopoulos et al.

    Value of dual-energy CT in differentiating focal fatty infiltration of the liver from low-density masses

    AJR

    (1991)
  • Cited by (135)

    • Ultrasound-based tissue characterization and classification of fatty liver disease: A screening and diagnostic paradigm

      2015, Knowledge-Based Systems
      Citation Excerpt :

      Furthermore, intra-hepatic vessels are visible and appear hypo-attenuated. In contrast, images of fatty liver show the liver more attenuated than the spleen, and the intra-hepatic vessels are not so distinguishable [88]. Various studies show that parameters, such as contrast agent injection rate and measurement delays influence the attenuation values, and this directly affects the evaluation threshold of hepatic steatosis [62,65].

    View all citing articles on Scopus
    View full text