Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Research Paper
  • Published:

A Miniature Optical Glucose Sensor Based on Affinity Binding

Abstract

A new concept for biosensors is introduced based on competitive displacement of an analyte and fluorescently-labeled counter-ligand for immobilized receptor sites. A small, optical, glucose sensor has been developed. The sensing element consists of a short length of hollow dialysis fiber remotely connected to a fluorimetry instrument via a single optical fiber. This sensing element contains a carbohydrate receptor, Concanavalin A, immobilized on its inner surface and a high molecular weight fluorescein labeled dextran as a competing ligand. Glucose in the external medium diffuses through the dialysis fiber into the sensing element and competes with dextran for binding to Con A. At equilibrium, the level of free fluorescein in the hollow fiber lumen is measured via the optical fiber and is correlated to the concentration of glucose. Preliminary results for glucose measurement in phosphate buffer and in blood are presented. Response is linear from 50 to 400 mg% glucose and response time is 5–7 minutes.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

References

  1. Symposium on Potentially Implanted Glucose Sensors. 1982. J. S. Soeldner (ed.), Diabetes Care 5: 147–283.

  2. Schultz, J.S. and Sims, G. 1979. Affinity Sensors for Individual Metabolites. Biotechnol. Bioeng. Symp. 9: 65–71.

    Google Scholar 

  3. Schultz, J.S. 1982. Optical Sensor of Plasma Constituents. U.S. Patent ♯4,344,438, August 17, 1982.

  4. Mansouri, S. 1983. Optical Glucose Sensor Based on Affinity Binding. Ph.D. Thesis, The University of Michigan.

  5. Belder, A.N. and Granath, K. 1973. Preparation and Properties of Fluorescein-Labeled Dextrans. Carbohydr. Res. 30: 375–378.

    Article  Google Scholar 

  6. So, L.L. and Goldstein, I.J. 1968. Protein-Carbohydrate Interaction XX. On the Number of Combining Sites on Concanavalin A, the Phytohemagglutinin of the Jack Bean. Biochim. Biophys. Acta 165: 398–404.

    Article  CAS  Google Scholar 

  7. Schultz, J.S., Mansouri, S. and Goldstein, I.J. 1982. Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites. Diabetes Care 5: 245–253.

    Article  CAS  Google Scholar 

  8. Sanderson, C.J. and Wilson, D.V. 1971. A Simple Method for Coupling Proteins to Insoluble Polysaccharides. Immunology 20: 1061–1065.

    CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mansouri, S., Schultz, J. A Miniature Optical Glucose Sensor Based on Affinity Binding. Nat Biotechnol 2, 885–890 (1984). https://doi.org/10.1038/nbt1084-885

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1038/nbt1084-885

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing