Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Protocol
  • Published:

Measurement of cardiac function using pressure–volume conductance catheter technique in mice and rats

Abstract

Ventricular pressure–volume relationships have become well established as the most rigorous and comprehensive ways to assess intact heart function. Thanks to advances in miniature sensor technology, this approach has been successfully translated to small rodents, allowing for detailed characterization of cardiovascular function in genetically engineered mice, testing effects of pharmacotherapies and studying disease conditions. This method is unique for providing measures of left ventricular (LV) performance that are more specific to the heart and less affected by vascular loading conditions. Here we present descriptions and movies for procedures employing this method (anesthesia, intubation and surgical techniques, calibrations). We also provide examples of hemodynamics measurements obtained from normal mice/rats, and from animals with cardiac hypertrophy/heart failure, and describe values for various useful load-dependent and load-independent indexes of LV function obtained using different types of anesthesia. The completion of the protocol takes 1–4 h (depending on the experimental design/end points).

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Figure 1: Pressure–volume (PV) catheters and main steps of the protocol.
Figure 2: Intubation techniques.
Figure 3: Surgical procedures for LV catheterization.
Figure 4: Occlusion techniques, aortic flow measurements and jugular vein injection.
Figure 5: Representative examples of rat and mouse baseline PV loops and occlusions.
Figure 6: Representative normal and pathological mouse baseline PV loops and occlusions, and example of hemodynamic effects of drug in mice and rats.
Figure 7: Representative example of noise and effects of filtration of volume/pressure signal on PV relations.

Similar content being viewed by others

References

  1. Sagawa, K., Maughan, W.L., Suga, H. & Sunagawa, K. Cardiac Contraction and the Pressure–Volume Relationship (Oxford University Press, New York, 1988).

  2. Kass, D.A., Yamazaki, T., Burkhoff, D., Maughan, W.L. & Sagawa, K. Determination of left ventricular end-systolic pressure–volume relationships by the conductance (volume) catheter technique. Circulation 73, 586–595 (1986).

    Article  CAS  Google Scholar 

  3. Burkhoff, D., Mirsky, I. & Suga, H. Assessment of systolic and diastolic ventricular properties via pressure–volume analysis: a guide for clinical, translational, and basic researchers. Am. J. Physiol. Heart Circ. Physiol. 289, H501–H512 (2005).

    Article  CAS  Google Scholar 

  4. Little, W.C. & Cheng, C.P. Effect of exercise on left ventricular-arterial coupling assessed in the pressure–volume plane. Am. J. Physiol. 264, H1629–H1633 (1993).

    CAS  PubMed  Google Scholar 

  5. Kass, D.A., Midei, M., Graves, W., Brinker, J.A. & Maughan, W.L. Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure–volume relationships in man. Cathet. Cardiovasc. Diagn. 15, 192–202 (1988).

    Article  CAS  Google Scholar 

  6. Georgakopoulos, D. et al. In vivo murine left ventricular pressure–volume relations by miniaturized conductance micromanometry. Am. J. Physiol. 274, H1416–H1422 (1998).

    CAS  PubMed  Google Scholar 

  7. Georgakopoulos, D. et al. The pathogenesis of familial hypertrophic cardiomyopathy: early and evolving effects from an alpha-cardiac myosin heavy chain missense mutation. Nat. Med. 5, 327–330 (1999).

    Article  CAS  Google Scholar 

  8. Nagayama, T. et al. Control of in vivo left ventricular [correction] contraction/relaxation kinetics by myosin binding protein C: protein kinase A phosphorylation dependent and independent regulation. Circulation 116, 2399–2408 (2007).

    Article  CAS  Google Scholar 

  9. Takimoto, E. et al. Chronic inhibition of cyclic GMP phosphodiesterase 5A prevents and reverses cardiac hypertrophy. Nat. Med. 11, 214–222 (2005).

    Article  CAS  Google Scholar 

  10. Takimoto, E. et al. Oxidant stress from nitric oxide synthase-3 uncoupling stimulates cardiac pathologic remodeling from chronic pressure load. J. Clin. Invest. 115, 1221–1231 (2005).

    Article  CAS  Google Scholar 

  11. Pacher, P. et al. Potent metalloporphyrin peroxynitrite decomposition catalyst protects against the development of doxorubicin-induced cardiac dysfunction. Circulation 107, 896–904 (2003).

    Article  CAS  Google Scholar 

  12. Georgakopoulos, D. & Kass, D.A. Estimation of parallel conductance by dual-frequency conductance catheter in mice. Am. J. Physiol. Heart Circ. Physiol. 279, H443–H450 (2000).

    Article  CAS  Google Scholar 

  13. Pacher, P., Batkai, S. & Kunos, G. Haemodynamic profile and responsiveness to anandamide of TRPV1 receptor knock-out mice. J. Physiol. 558, 647–657 (2004).

    Article  CAS  Google Scholar 

  14. Pacher, P. et al. Beneficial effects of a novel ultrapotent poly(ADP-ribose) polymerase inhibitor in murine models of heart failure. Int. J. Mol. Med. 17, 369–375 (2006).

    CAS  PubMed  PubMed Central  Google Scholar 

  15. Batkai, S. et al. Decreased age-related cardiac dysfunction, myocardial nitrative stress, inflammatory gene expression, and apoptosis in mice lacking fatty acid amide hydrolase. Am. J. Physiol. Heart Circ. Physiol. 293, H909–H918 (2007).

    Article  CAS  Google Scholar 

  16. Mukhopadhyay, P. et al. Pharmacological inhibition of CB1 cannabinoid receptor protects against doxorubicin-induced cardiotoxicity. J. Am. Coll. Cardiol. 50, 528–536 (2007).

    Article  CAS  Google Scholar 

  17. Pacher, P. et al. Left ventricular pressure–volume relationship in a rat model of advanced aging-associated heart failure. Am. J. Physiol. Heart Circ. Physiol. 287, H2132–H2137 (2004).

    Article  CAS  Google Scholar 

  18. Pacher, P. et al. A new, potent poly(ADP-ribose) polymerase inhibitor improves cardiac and vascular dysfunction associated with advanced aging. J. Pharmacol. Exp. Ther. 311, 485–491 (2004).

    Article  CAS  Google Scholar 

  19. Batkai, S. et al. Endocannabinoids acting at cannabinoid-1 receptors regulate cardiovascular function in hypertension. Circulation 110, 1996–2002 (2004).

    Article  CAS  Google Scholar 

  20. Batkai, S. et al. Endocannabinoids acting at CB1 receptors mediate the cardiac contractile dysfunction in vivo in cirrhotic rats. Am. J. Physiol. Heart Circ. Physiol. 293, H1689–H1695 (2007).

    Article  CAS  Google Scholar 

  21. Baan, J. et al. Continuous measurement of left ventricular volume in animals and humans by conductance catheter. Circulation 70, 812–823 (1984).

    Article  CAS  Google Scholar 

  22. Kass, D.A. & Maughan, W.L. From 'Emax' to pressure–volume relations: a broader view. Circulation 77, 1203–1212 (1988).

    Article  CAS  Google Scholar 

  23. Kass, D.A. et al. Influence of contractile state on curvilinearity of in situ end-systolic pressure–volume relations. Circulation 79, 167–178 (1989).

    Article  CAS  Google Scholar 

  24. Glower, D.D. et al. Linearity of the Frank–Starling relationship in the intact heart: the concept of preload recruitable stroke work. Circulation 71, 994–1009 (1985).

    Article  CAS  Google Scholar 

  25. Hanusch, C., Hoeger, S. & Beck, G.C. Anaesthesia of small rodents during magnetic resonance imaging. Methods 43, 68–78 (2007).

    Article  CAS  Google Scholar 

Download references

Acknowledgements

This research was supported by the Intramural Research Program of NIH/NIAAA (to P.P.). NIH-NHLBI HL-077180; HL-59408. We are indebted to Huntly Millar and Tim Daugherty for reading the protocol and valuable suggestions and acknowledge Millar Instruments for the permission to use animations in the movies and for providing background information on the use of Millar PV systems. P.P. dedicates this protocol to his beloved mother Iren Bolfert and grandmother Ilona Kerenyi.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Pál Pacher or David A Kass.

Supplementary information

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pacher, P., Nagayama, T., Mukhopadhyay, P. et al. Measurement of cardiac function using pressure–volume conductance catheter technique in mice and rats. Nat Protoc 3, 1422–1434 (2008). https://doi.org/10.1038/nprot.2008.138

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/nprot.2008.138

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing