Characterization of gradient-index lens-fiber spacing toward applications in two-photon fluorescence endoscopy

Not Accessible

Your library or personal account may give you access

Abstract

We report on the experimental investigation into the characterization of two-photon fluorescence microscopy based on the separation distance of a single-mode optical fiber coupler and a gradient-index (GRIN) rod lens. The collected two-photon fluorescence signal exhibits a maximum intensity at a defined separation distance (gap length) where the increasing effective excitation numerical aperture is balanced by the decreasing confocal emission collection. A maximum signal is found at gap lengths of approximately 2, 1.25, and 1.75 mm for GRIN lenses with pitches of 0.23, 0.25, and 0.29 wavelength at 830 nm. The maximum two-photon fluorescence signal collected corresponds to a threefold reduction of axial resolution (38.5 µm at 1.25 mm), compared with the maximum resolution (11.6 µm at 5.5 mm), as shown by the three-dimensional imaging of 10 µm beads. These results demonstrate an intrinsic trade-off between signal collection and axial resolution.

© 2005 Optical Society of America

Full Article  |  PDF Article
More Like This
Two-photon fluorescence endoscopy with a micro-optic scanning head

Damian Bird and Min Gu
Opt. Lett. 28(17) 1552-1554 (2003)

Super-resolution endoscopy for real-time wide-field imaging

Feifei Wang, Hok Sum Sam Lai, Lianqing Liu, Pan Li, Haibo Yu, Zhu Liu, Yuechao Wang, and Wen Jung Li
Opt. Express 23(13) 16803-16811 (2015)

Miniaturized two-photon microscope based on a flexible coherent fiber bundle and a gradient-index lens objective

Werner Göbel, Jason N. D. Kerr, Axel Nimmerjahn, and Fritjof Helmchen
Opt. Lett. 29(21) 2521-2523 (2004)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (4)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (2)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.